What a Thermal Break Actually Does
Aluminium conducts heat well — roughly 200 W/m·K for 6063. That is exactly what you want in a heat sink and exactly what you do not want in a window frame. A thermal break puts a low-conductivity barrier between the indoor and outdoor halves of the profile, so the frame stops acting as a radiator fin between a warm room and a cold façade.
Without that barrier, the inner face of the frame drops close to outdoor temperature in winter. Two things follow: condensation on the frame, and eventually mould at the reveal, plus a frame U-value high enough to pull down the whole window no matter how good the glass is.
Two Ways to Break the Bridge
Polyamide strip. The two aluminium halves are extruded separately, knurled, and crimped or rolled onto a glass-fibre-reinforced polyamide 66 strip. The strip carries the structural load across the gap. This is the dominant method for residential and commercial window systems.
Pour-and-debridge. The profile is extruded as one hollow chamber, filled with liquid polyurethane, cured, then the aluminium bridge at the bottom is milled away. Tooling is cheaper for simple shapes, but the debridging must be complete — a residual aluminium bridge is a thermal short that will not show up until the first winter.
Both are legitimate. What is not legitimate is a thermal-break claim on a profile where the two halves still touch at the screw port or the drainage lip. Ask for a cross-section drawing before you ask for a price.
U-Value: Separating the Frame from the Glass
Window U-value is an area-weighted combination of glass (Ug), frame (Uf), spacer and installation. Buyers routinely quote a whole-window figure from a brochure and then specify a frame that cannot support it.
For non-thermal-break aluminium, frame Uf commonly lands in the 5.5–6.5 W/m²K range. A properly executed polyamide break typically brings Uf to roughly 2.5–3.5 W/m²K, and wider breaks with foam inserts go lower. These are market ranges, not test results. The number that counts is the one in your project’s test report, calculated to EN ISO 10077-2 or measured to EN 12412-2.
Wall Thickness, Series Number and the Confusion Between Them
“Series 60” or “Series 70” refers to frame depth in millimetres, not to wall thickness. A 70 mm series with 1.4 mm walls is not stronger than a 60 mm series with 2.0 mm walls. It is deeper, which helps inertia and hardware space, but the load path is decided by the walls and the chambers.
Wall thickness is what belongs in the purchase order, with a tolerance. Architectural specifications commonly call for 1.4 mm minimum on visible members and 1.8–2.0 mm on structural mullions; some markets require more. Verify it by sectioning a sample, not with a caliper at the cut end.
Alloy and Temper
6063-T5 is the default for window and door profiles: good surface, adequate strength, predictable anodizing. 6063-T6 raises yield strength at some cost in elongation and dimensional control. Where a market demands higher strength or thinner walls, 6061-T6 appears — but 6061 anodizes to a duller finish that is harder to colour-match against adjacent panels.
Ask for temper on the mill certificate rather than inferring it from the invoice. T5 and T6 are different cooling rates and different furnaces, and the certificate is the only place that distinction survives.
Surface Finish in Coastal, Cold and High-UV Climates
Anodizing, typically 10–25 µm, gives a metallic finish with excellent abrasion resistance and no organic coating to chalk. Powder coating, typically 60–80 µm, gives colour range and better salt-spray resistance when the pretreatment is right. Pretreatment quality, not coating thickness, is where most coating failures start.
For coastal projects, ask for salt-spray hours together with the pretreatment sequence, and require a Qualicoat or Qualanod certificate where the specification calls for one. For high-UV markets, ask for colour-retention data, not only the initial gloss reading.
Where Leaks Actually Come From
Water and air leaks are rarely a profile problem. They come from tolerance stack-up: frame squareness, sash diagonal, gasket compression, and the gap between frame and structural opening.
Two numbers matter and are usually missing from the order — the straightness and twist tolerance of the extrusion, commonly 1–2 mm per metre for architectural profiles, and the permitted deviation on the mitre cut. If the fabricator’s saw tolerance is wider than the gasket can absorb, no amount of site silicone will fix it.
Drainage, Gaskets and Hardware Channels
A window frame is a drainage system. Check that the profile has a defined water path from the glazing rebate to the exterior weep, that the weep carries a baffle, and that inner and outer chambers are separated by a gasket rather than by hope.
Check hardware compatibility before tooling as well. A European T-slot, a 16 mm Eurogroove and a proprietary channel are not interchangeable, and changing hardware after extrusion means new dies.
Documents to Request
- Cross-section drawing with wall thickness and break width dimensioned
- Mill certificate: alloy, temper, chemical composition, mechanical properties
- Frame U-value test report with the standard cited
- Coating certificate plus salt-spray or colour-retention data
- An assembled mitre joint sample — not loose profiles
Cost Structure
A thermal break adds cost in four places: the polyamide strip itself, the knurling and crimping step, the second extrusion pass, and the scrap rate during setup. On a typical casement profile the break is a modest share of the profile price. On a wide sliding door it is larger, because the strip is wider and the section heavier.
Do not compare a thermal-break quote against a non-break quote on price per kilogram alone. Compare cost per square metre of finished window at equal U-value, and include the finishing route, because anodizing before assembly adds a handling step.
Specification Checklist
| Decision | Non-thermal-break | Thermal-break |
|---|---|---|
| Frame Uf, typical market range | 5.5–6.5 W/m²K | 2.5–3.5 W/m²K |
| Tooling | One die | Two dies, plus strip and crimping |
| Assembly steps | Cut, punch, assemble | Cut, insert strip, crimp, then assemble |
| Condensation risk on frame | High in cold climates | Low when the break is continuous |
| Finish route | Anodize or powder coat after extrusion | Anodize before assembly, or powder coat after |
| Best fit | Interior partitions, screens, warm climates | Exterior windows, cold and coastal climates, energy codes |
| Main cost driver | Metal weight | Strip width and assembly time |
FAQ: Three Questions Buyers Ask Every Week
Can a thermal break be added to an existing die? No. The two halves have to be designed as separate profiles from the start. Retrofitting means new dies.
Is a wider break always better? Wider breaks lower Uf, but they also reduce section stiffness and raise cost. Beyond roughly 24–30 mm the thermal gain flattens unless the cavity is foamed.
Does the break change the finishing process? Yes. The polyamide strip cannot survive an anodizing bath, so either the halves are anodized before assembly or the finished profile is powder coated. Both routes change lead time, and both should be written into the schedule before the order is placed.